Afterwards, we must configure the frequency weighting and testing duration. Typically, we select A-Weighted and Z (No Weight) settings. The 'No Weight' setting provides us with the unfiltered noise signal generated by the product, while the 'A-Weighted' setting simulates the response of the human ear.
It's worth noting that there are no specific regulations or standards governing testing duration. However, I'd like to offer some insights on this matter. To determine the optimal testing duration that balances reliable results and efficiency, we can conduct a mock-up test. This involves measuring the equivalent sound pressure for durations of 10 seconds, 30 seconds, 1 minute, and 2 minutes.
Subsequently, we should assess the deviation of results obtained at these time intervals in comparison to the 10-second measurement. If the deviation falls within the predefined criteria or less than 5%, we can confidently adopt the 10-second duration as our standard testing duration.